General engine data | |
Model | 6135HFG09 |
Number of cylinders | 6 |
Displacement-- L (cu in) | 13.5 (824) |
Bore and Stroke-- mm (in) | 132 x 165 (5.20 x 6.50) |
Compression Ratio | 15.3 : 1 |
Engine Type | In-line, 4 Cycle |
Aspiration | Turbocharged and air-to-air aftercooled |
Length - mm (in) | 1501 (59.1) |
Width-- mm (in) | 955 (37.6) |
Height-- mm (in) | 1551 (61.1) |
Weight, dry - kg (lb) | 1500 (3307) |
DOC/DPF Dimensions | |
Size 7 - Diameter - mm (in) | 331.7 (13.1) |
Size 7 - Length - mm (in) | 838 (33.0) |
Size 7 - Weight - kg (lb) | 66.4 (146.4) |
SCR Catalyst Dimensions | |
Size 7 - Diameter -mm(in) | 380.8 (15.0) |
Size 7 - Weight -kg(lb) | 67.5 (148.8) |
Size 7 - Length -mm(in) | 860.1 (33.9) |
Performance data range | |
Hz (rpm) | 60 ( 1800 ) |
Generator Efficiency % | 90-95 |
Power Factor | 0.8 |
Engine power - Prime kW | 326-433 |
Engine power - Prime hp | 437-580 |
Engine power - Standby kW | 356-473 |
Engine power - Standby hp | 477-634 |
Rated Fan Power - kW | 21.4-28.4 |
Rated Fan Power - hp | 28.7-38.1 |
Calculated generator set output - Prime kWe | 274-384 |
Calculated generator set output - Prime kVA | 342-480 |
Calculated generator set output - Standby kWe | 301-422 |
Calculated generator set output - Standby kVA | 376-528 |
Emissions Certifications | |
CARB | |
EPA Tier 4 | |
DOC/DPF Dimensions | |
Size 7 - Diameter - mm (in) | 331.7 (13.1) |
Size 7 - Length - mm (in) | 838 (33.0) |
Size 7 - Weight - kg (lb) | 66.4 (146.4) |
SCR Catalyst Dimensions | |
Size 7 - Diameter -mm(in) | 380.8 (15.0) |
Size 7 - Weight -kg(lb) | 67.5 (148.8) |
Size 7 - Length -mm(in) | 860.1 (33.9) |
Performance data range | |
Calculated generator set output - Prime kWe | 274-384 |
Calculated generator set output - Prime kVA | 342-480 |
Calculated generator set output - Standby kWe | 301-422 |
Calculated generator set output - Standby kVA | 376-528 |