General engine data | |
Model | 4045HFG93 |
Number of cylinders | 4 |
Displacement-- L (cu in) | 4.5 (275) |
Bore and Stroke-- mm (in) | 106 x 127 (4.17 x 5.00) |
Compression Ratio | 16.5 : 1 |
Engine Type | In-line, 4-cycle |
Aspiration | Turbocharged and air-to-air aftercooled |
Length - mm (in) | 867 (34.1) |
Width-- mm (in) | 680 (26.8) |
Height-- mm (in) | 1076 (42.4) |
Weight, dry - kg (lb) | 570 (1257) |
DOC/DPF Dimensions | |
Size 2 - Diameter - mm (in) | 260.71 (10.3) |
Size 2 - Length - mm (in) | 572.59 (22.5) |
Size 2 - Weight - kg (lb) | 21.364 (47.1) |
SCR Catalyst Dimensions | |
Size 5 - Diameter -mm(in) | 360.68 (14.2) |
Size 5 - Weight -kg(lb) | 47.17 (104.0) |
Size 5 - Length -mm(in) | 784.86 (30.9) |
Performance data range | |
Hz (rpm) | 60 ( 1800 ) |
Generator Efficiency % | 88-92 |
Power Factor | 0.8 |
Engine power - Prime kW | 95-113 |
Engine power - Prime hp | 128-151 |
Engine power - Standby kW | 105-124 |
Engine power - Standby hp | 141-166 |
Rated Fan Power - kW | 8.4-10.8 |
Rated Fan Power - hp | 11.3-14.5 |
Calculated generator set output - Prime kWe | 77-95 |
Calculated generator set output - Prime kVA | 96-119 |
Calculated generator set output - Standby kWe | 85-105 |
Calculated generator set output - Standby kVA | 106-131 |
Emissions Certifications | |
CARB | |
EPA Interim Tier 4 | |
DOC/DPF Dimensions | |
Size 2 - Diameter - mm (in) | 260.71 (10.3) |
Size 2 - Length - mm (in) | 572.59 (22.5) |
Size 2 - Weight - kg (lb) | 21.364 (47.1) |
SCR Catalyst Dimensions | |
Size 5 - Diameter -mm(in) | 360.68 (14.2) |
Size 5 - Weight -kg(lb) | 47.17 (104.0) |
Size 5 - Length -mm(in) | 784.86 (30.9) |
Performance data range | |
Calculated generator set output - Prime kWe | 77-95 |
Calculated generator set output - Prime kVA | 96-119 |
Calculated generator set output - Standby kWe | 85-105 |